ReignPower LP1150D-24MDA

SKU : LP1150D-24MDA

Price

2,715.00 THB

Quantity to buy
Total 2,715.00 THB

Do not have enough stock

Out of stock

Switching Power Supply

AC to DC Switching Power Supply

LP1150D Series



Features

Green Power

  • Din Rail / Screw Mounting Dual Purpose
  • Easy mounting (one-step installation)
  • Comply with high Efficiency Power 80Plus Criterion
  • "Output Voltage Monitor" Display
  • Convection cooled high reliability
  • 100% burn-in test
  • 1 years warranty
  • Output modify range: 3V~200VDC

DIMENSIONS : 100(H)*83(D)*49(W)mm WEIGHTS : 390g


General Specifications

INPUT

Input range 90~132/180~264VAC (Selectable) 220~380VDC

Input frequency 47~63Hz

Inrush current (25 ํC) 25A/110VAC 55A/220VAC


OUTPUT

Hold-up time 13ms

Short protection Autorecovery

Over load protection Automatic power limited

Constant output Current control by 0~5V terminal signal (Optional)

Optional 5V/3A AUX output

for models which output voltage lower than 40VDC


Detail specifications

150 Watts


Model

LP1150D-24MDA


O/P Volt Adj. ± %

V : +24V ± 10%


Load (Current)1

Min.

0A


Rated

2.1A


Max.

2.1A


Ripple & Noise 4

240mV


Line REG.2

±1%


Load REG.3

±1%


Efficiency5

86% Ref.


O.V.P

31.4~34.7V


Please Choose Fit Function, And Fill in The Blank With Suitable Words.

Order Model : LP1150D-24MDA [] [] []

Optional Function :

Terminal Block : " : PCB Barrier Terminal Block

"E" : Mini Terminal Block


Monitor: " " : No Monitor

"D" : Monitor Display


Type : " " : No Display function

"A" : Output Voltage Display


CE Standards

EN 55032, EN 55024, EN61000-3-3, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) LVD : EN60950-1


Safety Standards

UL 508 APPROVAL

CE Marking


Environments

Operating Temperature -15~50 ํC, Ambient

Operating Humidity 20~90% RH, No Condensing

Storage Temperature -20~85 ํC, Ambient

Vibration 2G, 10~500Hz, 3 axes


Note

1. Each output can provide up to maximum load, but total load can not exceed rated output power.

2. Line regulation is measured from low line to high line at rated load.

3. Load regulation is measured from 20% to 100% of rated load at 220VAC input.

4. Ripple & Noise are measured with 20MHz oscilloscope at 220VAC by using a 20cm long 12" twisted pair-wire with a 0.1uF/630V metal capacitor & a 47uf electrolytic capacitor parallel on the test point.

5. Efficiency is measured at rated load and 220VAC input.

6. Hold-up time is measured at rated load and 220VAC input.

7. With • are CE safety approval, but no UL safety approval.

8. Output Voltage Adjustable is measured on 5% of rated load.

9. Reign Power reserve the right to change specifications at any time without notice.

Visitors: 451,349